Inverter-Type refrigerators are known to consume less energy by varying the inverter frequency according to indoor temperatures and refrigerant pressure through indoor-outdoor communication. However, many commercial operators cannot afford to replace indoor units with ones capable of communication. In a non-communication configuration, indoor units are connected with an inverter-type outdoor unit without intercommunication abilities. The research goal is finding appropriate operating parameters to achieve energy efficiency. Thus, an operation algorithm with two modes is proposed, i.e., one to search the best operating parameters and one for normal operation with the best parameters. The experimental evaluation showed 11.27% reduction in energy consumption, indicating a good applicability of the algorithm.