Structural Behavior Analysis of the Proximal Femur after Artificial Hip Joint Implantation at Micro Level
Seung Hun Ryu, Jung Jin Kim
J. Korean Soc. Precis. Eng. 2023;40(11):873-879.
Published online November 1, 2023
DOI: https://doi.org/10.7736/JKSPE.023.054
Total hip replacement is a representative treatment for avascular necrosis of the femoral head. However, the stress shielding caused by the replacement induces dissociation of the artificial hip joint and various complications. Many studies have tried to explore the stress shielding but, most studies have been conducted at macro level and not at micro level. Thus, this study aimed to quantitatively analyze the structural behavior of the proximal femur according to total hip replacement at the micro level to explore the stress shielding. For this purpose, this study selected the artificial hip joint of the single wedge type and implanted the joint into a proximal femur that has a high resolution of 50 μm. Then the structural behavior of the implanted femur was analyzed by comparing that of the intact femur under three daily activity loads. As a result, the high possibility was confirmed that the stress shielding will occur in both cortical and cancellous bones under the one-legged stance movements. Additionally, it was discovered that the cancellous bone had a considerably lesser chance of adducting at an angle similar to the neck shaft angle of an artificial hip joint.
  • 5 View
  • 0 Download
Structural Behavior Analysis according to Porous Structures of the Bone Scaffold in the Femoral Head
최준원 , 김정진
J. Korean Soc. Precis. Eng. 2022;39(8):627-633.
Published online August 1, 2022
DOI: https://doi.org/10.7736/JKSPE.022.041
The bone scaffold is artificial mechanical support, that is implanted on collapsed bone microstructure. The clinical field has become interested in that, because it is free of immunological rejection. However, few studies have analyzed quantitively the mechanical interaction with the surrounding bone tissue, when the bone scaffold is implanted. Thus, the purpose of this study was to analyze structural behavior variance, according to porous structures of the bone scaffold. This study set the proximal femoral head as the implantation skeletal system, and defined bone scaffolds (i.e. triangular, rectangle, circular, honeycomb) with four porous structures. Then, structural behavior variance was analyzed, caused by the implantation of bone scaffolds. As a result, it was quantitatively confirmed that a porous structure such as a normal bone that can transmit and support an external load is important.

Citations

Citations to this article as recorded by  Crossref logo
  • Computational comparison study of virtual compression and shear test for estimation of apparent elastic moduli under various boundary conditions
    Jisun Kim, Jung Jin Kim
    International Journal for Numerical Methods in Biomedical Engineering.2024;[Epub]     CrossRef
  • Quantitative Load Dependency Analysis of Local Trabecular Bone Microstructure to Understand the Spatial Characteristics in the Synthetic Proximal Femur
    Jisun Kim, Bong Ju Chun, Jung Jin Kim
    Biology.2023; 12(2): 170.     CrossRef
  • Topology Optimization-Based Localized Bone Microstructure Reconstruction for Image Resolution Enhancement: Accuracy and Efficiency
    Jisun Kim, Jung Jin Kim
    Bioengineering.2022; 9(11): 644.     CrossRef