Skip to main navigation Skip to main content
  • E-Submission

JKSPE : Journal of the Korean Society for Precision Engineering

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS
Article

Development of a Metrological Atomic Force Microscope for the Length Measurements of Nanometer Range

Jong-Ahn Kim, Jae Wan Kim, Byong Chon Park, Tae Bong Eom, Jae Wan Hong
JKSPE 2004;21(11):75-82.
Published online: November 1, 2004
  • 2 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

A metrological atomic force microscope (M-AFM) was developed for the length measurements of nanometer range, through the modification of a commercial AFM. To eliminate nonlinearity and crosstalk of the PZT tube scanner of the commercial AFM, a two-axis flexure hinge scanner employing built-in capacitive sensors is used for X-Y motion instead of PZT tube scanner. Then two-dimensional displacement of the scanner is measured using two-axis heterodyne laser interferometer to ensure the meter-traceability. Through the measurements of several specimens, we could verify the elimination of nonlinearity and crosstalk. The uncertainty of length measurements was estimated according to the Guide to the Expression of Uncertainty in Measurement. Among several sources of uncertainty, the primary one is the drift of laser interferometer output, which occurs mainly from the variation of refractive index of air and the thermal stability. The Abbe error, which is proportional to the measured length, is another primary uncertainty source coming from the parasitic motion of the scanner. The expanded uncertainty (k = 2) of length measurements using the M-AFM is √(4.26)²+(2.84×10-⁴×L)² (㎚), where L is the measured length in ㎚. We also measured the pitch of one-dimensional grating and compared the results with those obtained by optical diffractometry. The relative difference between these results is less than 0.01 %.

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Development of a Metrological Atomic Force Microscope for the Length Measurements of Nanometer Range
J. Korean Soc. Precis. Eng.. 2004;21(11):75-82.   Published online November 1, 2004
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Development of a Metrological Atomic Force Microscope for the Length Measurements of Nanometer Range
J. Korean Soc. Precis. Eng.. 2004;21(11):75-82.   Published online November 1, 2004
Close