Skip to main navigation Skip to main content
  • E-Submission

JKSPE : Journal of the Korean Society for Precision Engineering

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS
Article

Analysis on the Effect of Lordosis Changes at Lumbar Joint using 3-dimensional Musculoskeletal Model

Tae Soo Bae, Shin Ki Kim, Je Chung Ryu, Mu Seong Mun
JKSPE 2009;26(10):116-121.
Published online: October 1, 2009
  • 2 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

It is important to consider lumbar lordotic angle for setup of training program in field of sports and rehabilitaton to prevent unexpected posture deviation and back pain. The purpose of this study was to analyze the biomechanical impact of the level of lumbar lordosis angle during isokinetic exercise through dynamic analysis using a 3-dimensional musculoskeletal model. We made each models for normal lordosis, excessive lordosis, lumbar kyphosis, and hypo-lordosis according to lordotic angle and inputted experimental data as initial values to perform inverse dynamic analysis. Comparing the joint torques, the largest torque of excessive lordosis was 16.6% larger and lumbar kyphosis was 11.7% less than normal lordosis. There existed no significant difference in the compressive intervertebral forces of each lumbar joint (p>0.05), but statistically significant difference in the anterioposterior shear force (p<0.05). For system energy, lumbar kyphosis required the least and most energy during flexion and extension respectively. Therefore during the rehabilitation process, more efficient training will be possible by taking into consideration not simply weight and height but biomechanical effects on the skeletal muscle system according to lumbar lordosis angles.

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Analysis on the Effect of Lordosis Changes at Lumbar Joint using 3-dimensional Musculoskeletal Model
J. Korean Soc. Precis. Eng.. 2009;26(10):116-121.   Published online October 1, 2009
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Analysis on the Effect of Lordosis Changes at Lumbar Joint using 3-dimensional Musculoskeletal Model
J. Korean Soc. Precis. Eng.. 2009;26(10):116-121.   Published online October 1, 2009
Close