The repeated unit cell structure is applied to the composite, the carbon nano tube and sandwich panel. In this paper, a study on the stiffness of unit cell structure has been performed with the tube support plate of the steam generator. For this, repeated unit cell structure’s equivalent elastic constant and poisson’s ratio was evaluated through FEA and tests under the elastic range load. Also we evaluated the effect on the specimen size from results.