스마트폰을 이용한 걸음걸이 시 다리분절과 관절 각도 측정의 신뢰도 연구

Study on the Reliability of Smartphone-Based Measurements of Leg Segment and Joint Angles During Gait

Journal of the Korean Society for Precision Engineering 2019;36(3):293-300.
Published online: March 1, 2019

1 유원대학교 물리치료학과

1 Department of Physical Therapy, U1 University

#E-mail: lovewisd@yd.ac.kr, TEL: +82-43-740-1404
• Received: January 12, 2018   • Revised: July 14, 2018   • Accepted: August 16, 2018

Copyright © The Korean Society for Precision Engineering

This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 46 Views
  • 0 Download
  • 2 Crossref
  • 2 Scopus
prev next

Citations

Citations to this article as recorded by  Crossref logo
  • Reliability of Measuring Leg Segments and Joint Angles Using Smartphones during Aquatic Exercise
    Dae Hee Lee, Seulki Han
    Healthcare Informatics Research.2022; 28(1): 95.     CrossRef
  • Drift Reduction in IMU-based Joint Angle Estimation for Dynamic Motion-Involved Sports Applications
    Jung Keun Lee, Chang June Lee
    Journal of the Korean Society for Precision Engineering.2020; 37(7): 539.     CrossRef

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Study on the Reliability of Smartphone-Based Measurements of Leg Segment and Joint Angles During Gait
J. Korean Soc. Precis. Eng.. 2019;36(3):293-300.   Published online March 1, 2019
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Study on the Reliability of Smartphone-Based Measurements of Leg Segment and Joint Angles During Gait
J. Korean Soc. Precis. Eng.. 2019;36(3):293-300.   Published online March 1, 2019
Close

Figure

  • 0
  • 1
  • 2
  • 3
  • 4
Study on the Reliability of Smartphone-Based Measurements of Leg Segment and Joint Angles During Gait
Image Image Image Image Image
Fig 1. Study design
Fig. 2 Attachment of smartphones on the torso, thigh, and shin
Fig. 3 Gait measurement with the smartphones attached
Fig. 4 Segmental angles from the first and second measurements
Fig. 5 Joint angles from the first and second measurements
Study on the Reliability of Smartphone-Based Measurements of Leg Segment and Joint Angles During Gait
Subject Mean ± SD
Sex (M/F) 4/4
Age (yr) 20.5 ± 0.926
Height (cm) 167.05 ± 7.962
Weight (kg) 63.875 ± 11.618
Mean ± SD ICC
First Second
Torso 2.259 ± 5.212 1.111 ± 4.311 0.975**
Thigh 6.809 ± 2.998 6.786 ± 5.688 0.737*
Shin -6.307 ± 4.83 -3.452 ± 7.717 0.909**
Mean ± SD ICC
First Second
Hip joint 4.55 ± 4.572 5.675 ± 4.361 0.632*
Knee joint 13.117 ± 3.089 10.237 ± 4.317 0.626*
Table 1 Demographic characteristics of the subjects
Table 2 Agreement of segmental angles

*ICC>0.60, **ICC>0.75

Table 3 Agreement of joint angles